An overview of ACI 533.5R-20, Guide for Precast Concrete Tunnel Segments, and ACI 544.7R-16, Report on Design and Construction of Fiber-Reinforced Precast Concrete Tunnel Segments, adapted from a presentation to the ASCE National Capital Section.

Tunnel segments are generally reinforced to resist tensile and compressive stresses at both the ultimate limit state (ULS) and the serviceability limit state (SLS). This article walks through where segmental linings came from, why fiber reinforced concrete (FRC) has become a strong option for them, and how the ACI guidance frames design across the life of a segment, from casting to long term service.

What this covers

Ultimate Limit State (ULS): making sure the lining can carry maximum loads without collapse.

Serviceability Limit State (SLS): keeping the lining functional under normal use, including crack control and durability.

Outside the scope

  • Gasket design as sealing elements
  • Connection devices and fastening systems
  • Segment tolerances, measurement, and dimensional control systems

History of tunnel liners

Tunnel lining goes back to the earliest underground construction, when timber and masonry held the ground open. The industrial revolution brought real advances in tunnel engineering, most famously the Thames Tunnel in London (1825 to 1843), which used cast iron segments for its lining.

Precast concrete tunnel segments

Mechanized tunneling is advancing quickly, driven by the broader move toward mechanization and automation in construction. The benefits are clear:

  • Improved occupational health and safety
  • Faster advance rates
  • Lower construction labor requirements

Segmental linings are the standard companion to tunnel boring machine (TBM) construction. Segments are erected ring by ring inside the shield as the machine advances.

Common terms

  • Annular gap: space between the surrounding ground and the outer surface of the segments.
  • Circumferential joint: joint roughly perpendicular to the tunnel axis, between two adjacent rings.
  • Longitudinal joint: joint between adjacent segments in a ring, with its axis parallel to the tunnel axis. Also called a radial joint.
  • Guiding rod: rod shaped accessory placed in longitudinal joints along the centroid of two adjacent segments.
  • Extrados: outer surface of the segment or ring, on the side in contact with the ground.
  • Intrados: inner surface of the segment or ring, on the tunnel side.
  • Crown: highest point of the tunnel cross section.
  • Springline: opposite ends of the horizontal centerline of the tunnel.
  • Invert: lowest point of the tunnel cross section.

Why material performance matters

Tunnels face demanding structural and environmental conditions, so durable, high performance materials are essential for:

  • Structural integrity and longevity under large loads from the surrounding ground and traffic above
  • Resistance to moisture, temperature variation, and corrosive chemicals
  • Safety and stability over the design life
  • Cost efficiency and reduced maintenance

Basics of fiber reinforced concrete

Fiber reinforced concrete is a composite of concrete and discrete fibers that improve its structural integrity and durability. Plain concrete is strong in compression but weak in tension, which makes it prone to cracking and brittle failure. Fibers bridge cracks, improving ductility, impact resistance, and overall toughness, meaning the material’s ability to absorb energy and deform without fracturing.

Steel fibers

Hooked, crimped, or straight fibers of carbon or stainless steel that raise tensile capacity, ductility, and resistance to impact and fatigue. Steel fiber reinforced concrete (SFRC) is widely used in tunnel linings, industrial floors, airport pavements, and precast elements.

Synthetic fibers

Polypropylene, nylon, and polyethylene fibers are lightweight and non corrosive. They improve shrinkage resistance and chemical durability, and are especially useful for controlling plastic shrinkage cracking.

Glass fibers

Glass fiber reinforced concrete (GFRC) offers high tensile strength, corrosion resistance, and good appearance, which makes it a common choice for facades, cladding panels, and architectural precast.

Advantages of FRC in tunnel segments

  • Less conventional reinforcement. Fibers reduce or replace rebar cages and mesh, cutting labor cost and production time.
  • Durability. FRC performs well under dynamic loads, chemical attack, and severe exposure.
  • Crack control. FRC generally produces smaller crack widths and better durability over the life of the structure.
  • Bursting and spalling resistance. Because fibers are dispersed throughout the segment, including near the faces, they resist the bursting and spalling stresses that develop under TBM jacking (Schnütgen 2003).
  • Impact and fatigue resistance. Fibers help segments tolerate accidental impacts during handling and construction (di Prisco and Felicetti 2004).

Rebar, fibers, or both

Reinforcing bar is efficient for localized stresses, such as those from concentrated loads during production. Distributed stresses, such as those from earth and groundwater pressure in the final service stage, are better handled by fiber reinforcement.

Since tunnel linings usually see both, segments can be produced with a hybrid of conventional bars and fibers. The slenderness of the segment (λ) guides the choice: when slenderness exceeds 10, a hybrid of fibers and conventional bars is generally needed.


Load and resistance factor design

ACI recommends that precast concrete tunnel segments be designed using the load and resistance factor design (LRFD) method, checking every stage a segment goes through:

  1. Production and transient stages
  2. Construction stages
  3. Service stages
Load caseRequired strength (U)
Load Case 1: stripping (demolding)U = 1.4w
Load Case 2: storageU = 1.4(w ± F)
Load Case 3: transportationU = 1.4(w ± F)
Load Case 4: handlingU = 1.4w
Load Case 5: thrust jack forcesU = 1.0J (1.2 if maximum machine thrust is unknown)
Load Case 6: tail skin groutingU = 1.25(w ± Pgr)
Load Case 7: secondary groutingU = 1.25(w ± Pgr)
Load Case 8: earth pressure and groundwater loadU = 1.25(w ± WAp) ± 1.35(EH + EV) ± 1.5P0
Load Case 9: longitudinal joint burstingU = 1.25(w ± WAp) ± 1.35(EH + EV) ± 1.5P0
Load Case 10: additional distortionU = 1.4Mdistortion
Where w is self weight; F is self weight of segments stacked above; J is TBM jacking force; Pgr is grout pressure; WAp is groundwater pressure; EV and EH are vertical and horizontal ground pressure; P0 is surcharge load; Mdistortion is the additional distortion effect. Source: ACI 533.5R-20.

Production and transient stages

These loads cover everything from casting until the segment is erected inside the TBM shield. The governing cases are typically:

  • Load Case 1: segment stripping
  • Load Case 2: segment storage

Construction stages

TBM thrust. Jacks bear on pads along the exposed circumferential joint. The high compression under each pad creates significant bursting tensile stresses deep within the segment, and spalling tensile forces between adjacent pads along the joint.

Grouting pressure. Grout injected into the annular gap pushes against the exterior of completed rings. AASHTO DCRT-1 sets the maximum permissible grouting pressure on the ring at 10 psi (69 kPa) above groundwater pressure.

Secondary grouting. Because secondary grouting happens long after the primary grout has cured, the lining can be assumed to be in full contact with the ground except in the local area being grouted.

Service stages

In service, segments carry vertical and horizontal earth pressure, groundwater, self weight, surcharge, and ground reaction loads.

Longitudinal joint bursting. Hoop forces from permanent earth and groundwater pressure pass through a reduced section at the longitudinal joints, where gaskets and stress relief grooves sit. This creates bursting tensile stresses along those joints, similar to the effect of TBM thrust on circumferential joints.

Additional distortion. Extra distortion can develop during ring assembly from joint misalignment, yielding of connectors, or excessive grouting pressure. Design for a minimum additional diametrical distortion of 0.5 percent of the diameter.


References

  • ACI Committee 533. ACI 533.5R-20: Guide for Precast Concrete Tunnel Segments. American Concrete Institute, 2020.
  • ACI Committee 544. ACI 544.7R-16: Report on Design and Construction of Fiber-Reinforced Precast Concrete Tunnel Segments. American Concrete Institute, 2016.
  • AASHTO. Technical Manual for Design and Construction of Road Tunnels: Civil Elements (DCRT-1).
  • Schnütgen, B. (2003).
  • di Prisco, M., and Felicetti, R. (2004).